Appendix A – CANopen Object Dictionary 113
1018 0 Identity U8 R 4 Number of entries
Range: 1…4
1 Vendor ID U32 R - Value 0xB7 = ABB Drives
2 Product code U32 R - Product code read from
the drive. Eg, value
0x1F7 = ACS355,
0x20A = ACSM1 speed,
0x20B = ACSM1 motion,
0x21C = ACS850, 0x259 =
ACS880.
3 Revision U32 R - FBA firmware version number
(hex), eg, value 0x015 =
FFEPL015
4Serial
number
U32 R - Serial number of the adapter
module
1020 0 Verify
configuration
U8 R 4 Number of entries
Range: 2…4
1 Configuration
date
U32 RW 0 Used by the MN to verify if the
module is properly configured
2 Configuration
time
U32 RW 0 Used by the MN to verify if the
module is properly configured
3 Configuration
ID
U32 RW 0 Used by the MN to verify if the
module is properly configured
4Verify
configuration
valid
BOOL RW TRUE Used by the MN to verify if the
module is properly configured
Index SI Name Type Acc. Def. Information