EasyManua.ls Logo

ABB IRB 920 - Page 953

ABB IRB 920
1008 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Correct synchronization position of axes 3 and 4
When jogging the manipulator to synchronization position, it is extremely important
to make sure that axes 3 and 4 are positioned correctly.
Note
At delivery the manipulator is in the correct position. Do NOT shift axis 3 or rotate
axis 4 at power up before the revolution counters are updated.
If axis 4 is rotated one or more turns from its calibration position before updating
the revolution counter, the correct calibration position will be lost due to
non-integer gear ratio. This will further affect the calibration position of axis 3.
Continues on next page
Product manual - IRB 920 953
3HAC075721-001 Revision: C
© Copyright 2022 ABB. All rights reserved.
6 Calibration
6.3.1 Updating revolution counters on OmniCore robots
Continued

Table of Contents

Related product manuals