Note/IllustrationAction
xx2100001339
Remove the attachment screws.3
Take out the incoming mains connector.4
Removing the power unit
Note/IllustrationAction
xx2100001333
Pull the cable ties out from the locking
holes.
Tip
Take photos of the cable ties and locking
holes before pulling out, to have as a
reference when refitting the cable ties.
1
Disconnect:
A1.X13 - A2.X12
A1.X2 - T4.X17
A1.X11 - T4.X13
A2.X13 - G1/G2.X1
A1.X6 - A2.X11
2
Continues on next page