EasyManua.ls Logo

ABB OmniCore E10 - Troubleshooting the Flexpendant

ABB OmniCore E10
230 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.3.2 Troubleshooting the FlexPendant
Description
The FlexPendant communicates with the computer and logic unit. The FlexPendant
is physically connected to the panel board. The cable contains the +24 V supply,
two enabling device chains and emergency stop.
Procedure
The procedure below describes what to do if the FlexPendant does not work
correctly.
NoteAction
See Operating manual - Omni-
Core.
Try resetting the FlexPendant using the reset
button located next to the USB port.
1
Note
If protective gloves are used, these
must be compatible with touch-
screens when using the FlexPend-
ant.
If the FlexPendant is not responding or does not
operate correctly, see Problem starting or con-
necting the FlexPendant on page 176.
2
Check the cable for connections and integrity.3
Check the 24 V power supply.4
Read the error event log message and follow any
instructions of references.
5
For more information on the FlexPendant, see Operating manual - OmniCore.
Product manual - OmniCore E10 187
3HAC079399-001 Revision: C
© Copyright 2019-2022 ABB. All rights reserved.
6 Troubleshooting
6.3.2 Troubleshooting the FlexPendant

Table of Contents

Related product manuals