6.3.2 Troubleshooting the FlexPendant
Description
The FlexPendant communicates with the computer and logic unit. The FlexPendant
is physically connected to the panel board. The cable contains the +24 V supply,
two enabling device chains and emergency stop.
Procedure
The procedure below describes what to do if the FlexPendant does not work
correctly.
NoteAction
See Operating manual - Omni-
Core.
Try resetting the FlexPendant using the reset
button located next to the USB port.
1
Note
If protective gloves are used, these
must be compatible with touch-
screens when using the FlexPend-
ant.
If the FlexPendant is not responding or does not
operate correctly, see Problem starting or con-
necting the FlexPendant on page 176.
2
Check the cable for connections and integrity.3
Check the 24 V power supply.4
Read the error event log message and follow any
instructions of references.
5
For more information on the FlexPendant, see Operating manual - OmniCore.
Product manual - OmniCore E10 187
3HAC079399-001 Revision: C
© Copyright 2019-2022 ABB. All rights reserved.
6 Troubleshooting