Note/IllustrationAction
xx1800001748
Disconnect two connectors to the Flex-
Pendant.
5
xx1800001192
Remove the power cable.6
Refitting the power cable and power cable cover
Note/IllustrationAction
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 41.
1
Continues on next page
Product manual - OmniCore E10 159
3HAC079399-001 Revision: C
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.4.1 Replacing the power cable and power cable cover
Continued