NoteAction
If it is not connected, repair the
connection and go to step six.
Check that the FlexPendant cable is correctly
connected to the extension cable.
3
Check the pins in the connector.
If it is ok, go to the next step.
• If damage is found, replace
the FlexPendant cable and
go to step six.
• If it is ok, go to the next
step.
Check the FlexPendant cable for any damage.4
If possible, test by connecting another FlexPend-
ant. This is to eliminate the FlexPendant and cable
as error sources; Test the FlexPendant with a
different controller to eliminate the controller as
error source.
5
If it is not ok, contact your local
ABB.
Check that the FlexPendant works normally.
Tip
This is detailed in section Troubleshooting the
FlexPendant on page 187.
6
Product manual - OmniCore E10 179
3HAC079399-001 Revision: C
© Copyright 2019-2022 ABB. All rights reserved.
6 Troubleshooting
6.2.5 Problem starting or connecting the FlexPendant