High voltage warningA
Status LEDB
Description
The status indicator LED can be used to identify the following status
during startup/power on:
1 Red, steady: Default when power is available.
2 Red, flashing: Power is on, self-test is ongoing, operating system
is loading.
3 Green, flashing: Application is loaded and initializing.
4 Green, steady: Power unit is operational.
If the LED does not turn steady green after 30-60sec, then the status
indicator LED can be used to identify the following issues:
• No color: Power to the power unit is missing.
• Red, steady: Internal error.
• Red, flashing: Firmware error or self-test failure.
Power unit status
LED
• No color: Voltage between DC+ - DC- ≤ 60 VDC
• Red: Voltage between DC+ - DC- > 60 VDC
High voltage warn-
ing