- 27 -
000522BG
2 - Characteristics
Power reduction due to the input voltage
The reduction of the power supplied where the DC input voltage values
are too high or too low is adjusted automatically.
Vin (V)
Pout (kW)
0
5
10
15
20
25
30
35
45
50
40
300
350
400
450
500
550
600
650
700
750
800
850
900
950
1000
Pout
Pin
Output power Vs Input voltage
Power reduction due to the grid voltage
The reduction of the power supplied where the grid voltage values are
too high or too low is adjusted automatically.
Grid voltage U/Un (%)
Output power (P/Pn, Q/Qn, S/Sn) (%)
0
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%(Pacr)
80
85
90
95
93.7
100
105
110
115
120
125
Output power Vs Grid voltage