Switch Country Grid Standard
1 2
2 F CHINA HV @ 400V
3 0 DENMARK TR-B @ 400V
3 6 DUBAI MV
3 7 DUBAI LV EX
3 C JORDAN @ 400V
3 E CHILE MV @ 400V
3 F IEC 62116 @ 400V
The inverter is congured using the rotary switches a05. Before adjusting
the rotating switches, make sure that the inverter is turned off! The table
shows which country grid standard and which menu language are
assigned to the various positions of rotary switches a05
The list of grid standards provided in the table was valid at the time of issue of the manual. It
will be continually updated as new country grid standards with which the inverter is compatible
are introduced.
If the grid standard for the country of installation is not on the list, its
presence can be checked using the "Aurora Manager Lite" software
when the inverter is rst switched on. Then turn the switches a05, and
the grid standard for the position set will be displayed.
During this phase the inverter is on, so pay particular attention and always wear suitable
protective equipment (for example, Class 0 Category RC insulating gloves).
The default setting is on 0 / 0 and means that there is no grid standard
selected.
Saving the country grid standard and language
The settings are frozen after the inverter has been in operation for 24
hours (it does not matter whether or not it is connected to the grid, it only
has to be under power).
The time remaining before the settings are frozen can be viewed using
the "Aurora Manager Lite" software.
Once the settings have been frozen nothing will happen if the rotating switches are turned.