Commissioning
System Manual
65
The physical address of a device is principally the same for all devices. The address consists of
4 parts. Part 1 designates the building, part 2 the storey/floor, part 3 the unit on a storey and
part 4 the device in a unit.
When buildings, floors or units are added, the address for the devices is counted upwards.
Depending on the device or operating mode the same address is assigned or only the
necessary part thereof.
Building
Address
Floor
Address
Unit
Address
Device
Address
Indoor station 1 ... 999 01 ... 64 01 ... 32 01 ... 08
Outdoor station
(Public) *
1 … 999 ― ― 01 ... 64
Outdoor station
(Private) *
1 ... 999 01 ... 64 01 ... 32 01 ... 64
Outdoor station
(Perimeter) *
― ― ― 1 … 32
Guard unit ― ― ― 1 … 32
Management
Software
― ― ― ―
IP switch actuator
(Network)
― ― ― 01 ... 32
IP switch actuator
(Building)
1 ... 999 ― ― 01 ... 32
IP switch actuator
(Private)
1 ... 999 01 ... 64 01 ... 32 01 ... 32
* A public outdoor station is the central outdoor station of a multi-party building. A private
outdoor station belongs to a unit (e.g. office or apartment). A perimeter outdoor station
belongs to a common facility, e.g. to a parking garage.