137
Restart the filter: Restart of the filter algorithm
Forklift filter: This is a filter to detect the shape of forklifts and ignore heat radiated from them
(e.g. in cold storage).
Restart the filter: Restart of the filter algorithm
8.9.2 Advanced settings
Configuration:You can choose between normal and expert mode. The differences are explained in the
following section.
Unit temperature:
Normal mode:
In normal mode, temperatures are measured and evaluated in the entire scene. It is not possible to mark
reports.
The operation of the monitoring is exclusively the monitoring of the rising temperature, with 2 alarm thresholds
(pre-alarm and alarm threshold).
Emissivity: The emissivity depends on the material and indicates how well a body can emit
thermal radiation.
The practical value of 0.96 is preset.
Options: Custom, or by surface roughness (Rough ~ Smooth) Rougher, Rough,
Smooth, Smoother (see section 8.9.5 for examples).
Distance: Distance between thermal imaging camera and measuring object
Pre-alarm threshold: Temperature value above which a pre-alarm is to be triggered.
The pre-alarm information can be displayed by the ABUS CMS software or ABUS
Link Station as a push function.
For cameras with 2 relay outputs (e.g. IPCA64581D), a distinction can also be
made between pre-alarm and full alarm via different relay outputs.
Filter time: Time period for which a temperature threshold must be maintained or exceeded
before a pre-alarm is triggered.
Alarm threshold: Temperature value above which a (full) alarm is to be triggered.
Filter time: Time period for which a temperature threshold must be maintained or exceeded
before a (full) alarm is triggered.
Pre-alarm output: A1 (or A2, if present)
Alarm output: A1 (or A2, if present)