69
AcuRev 1300
Table 5-9 Independent Control Relay Query
Addr Fun
DO addr
HI
DO addr
LO
Value
HI
Value
LO
CRC16
HI
CRC16
LO
11H 05H 00H 00H FFH 00H 8EH AAH
The response data frames:
Is a normal response to this command request after the relay state changes back to
receive data.
Table 5-10 Independent Relay Control Response Response
Addr Fun
DO addr
HI
DO addr
LO
Value
HI
Value
LO
CRC16
HI
CRC16
LO
11H 05H 00H 00H FFH 00H 8EH AAH