4-12 ADS TRITON+ Manual
Length Enter the total length of the wall, from one
side of the chamber to the other.
Height Enter the distance from the bottom of the
channel to the initial elevation on the crest wall at
which the flow will begin to traverse (or flow over)
the wall.
Breadth Enter the thickness of the crest wall from
the upstream edge of the weir to the downstream edge.
Flume
Range Enter the distance from the face of the sensor
to the bottom (i.e., floor) of the flume at the
designated measurement point for the flume.
Width Enter the distance across the throat of the
flume.
Capacity Enter the maximum capacity of the flume
based on any parameters applied and/or measurements
taken at the location for the application.
Lookup
Height Enter the distance from the bottom of the
pipe to the crown of the pipe.
Click on the Display button to open the Lookup Table
dialog and enter the following parameters on the dialog: