Maintenance and Troubleshooting 11-65
Velocity data seems erratic or exhibits poor quality.
transmit/receive surfaces may be dirty.
Sensor may be close to extending out of the flow.
Designated value for the maximum velocity parameter
may be too high, creating too broad of a range.
setting may be incorrect.
Processor board may be faulty.
Clean the sensor’s transmit/receive surfaces.
Verify whether the flow depth exceeds the sensor
deadband at the same time and under the same
conditions as the erratic data. Rotate the sensor further
toward the center of the pipe if possible.
Transmit Frequency
. It should be set to
High
for optimal performance.
Reduce the maximum velocity in the device parameters
to narrow the range.
Check the sensor connections.
Contact your regional ADS representative.
Replace the monitor if defective.
Velocity readings are abnormally high.
Sensor’s velocity transmit/receive surfaces may be
covered with silt or other debris.
setting may be too high.
Sensor may be extending out of the flow.
Flow may be reversed or slower than (0.5
feet per
Check the site conditions, and relocate the sensor if
necessary.
Check the velocity parameters.