A-8 ADS TRITON+ Manual
jacket
Extension cables available up to 300 feet (91.4
m)
Operating /
Storage
Temperature
Operating:
-4° to 140° F (-20° to 60° C)
Storage:
-4° to 167° F (-20° to 75° C)
Note:
This sensor will not produce accurate
readings in frozen flow.
Upward Ultrasonic Depth
Upward Depth
Accuracy
0.5% of reading or +/- 0.125 inches (3.2 mm),
whichever is greater
Deadband
Extending 1.0 inch (25 mm) up from
the bottom of the sensor
Frequency
250 kHz
1 MHz
Range
60
inches (1829 mm)
Resolution
0.01 inches
(0.25 mm)
Drift
0
Peak Doppler Velocity
Range
-30 to 30 feet per second (
-9.1 to 9.1 m/sec)
Deadband
Extending 1.0 inch (25 mm) up from
the bottom of the sensor
Frequency
250 kHz
1 MHz
Resolution
0.01
feet per second (0.003 m/sec)
Accuracy
+/
-
0.2 ft/sec (0.06 m/sec) or 4% of actual peak
velocity (whichever is greater) in flow velocities
from
-5 to 20 ft/sec (-1.52 to 6.10 m/sec)
Pressure Depth
Pressure Range
0.0 to 10.0 PSI (0.0 - 0.68 Bar): up to 23.06 feet
(7.03 m)
Pressure
Accuracy
0 - 10.0 PSI (0 - 0.68 Bar): +/- 2.8 inches (70.3
mm)

Table of Contents