Table 1. CAM instruction menu functions
5.4
CAM Instruction Configuration File
The CAMTEACH.CT order of the CAM instruction file is explained as follows.
CTSTART: Configure the starting mark for the file
CTEND: Configure the ending mark for the file
CAMINFO: Starting mark of CAM data
A: CAM type, parameter range 1-30. Currently it supports 30 types at most and can be expanded according to
the situation.
B: Number of parameters
C: CAM picture saving path, for example: 0:\\ADT\\CAMTEACH\\G151.bmp
D: Picture type: 380x380
E: The correspondent G code is G151-G180
G: The value after the parameter is the initial value involved by FGH.
F: Parameter name definition involved by FGH. The first CAM parameter is suggested to be used as
note.
H: Value range involved by FGH. The first value is a minimum one and the second a maximum one.
The examples of the ‘CAMTEACH.CT’ of the CAM instruction file are as follows.
(Format description)
(A CAM type, parameter range 1-30)
(B Number of parameters)
(C Picture saving path, for example: 0:\\ADT\\CAMTEACH\\G151.bmp)
(D Picture type: 240x180 800x480)
(E The correspondent G code G151-G180)