EasyManua.ls Logo

ADTRAN Total Access 372 - Commissioning and Testing; Turn-Up

ADTRAN Total Access 372
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Total Access 372 Small Business Unit ONT Installation and Maintenance Guide
32 61287722G1-5B
Commissioning and Testing
Thissectionprovidesdetailedinformationonthefollowing :
“TurnUp”
•Dependingonthelocalserviceprov ider’srequirementsthetechnicianmayberequiredto
performadditionaltestsbeyondtheSBUONTontheCustomerProvidedEquipment
(CPE)wiringand/orequipment.Ifthisisthecase,apowermetermaybeusedtotestthe
upstreamanddow
n
streamsignaltypesforvoice,data,andvideo
“SecuretheUnit”onpage 33
“Testfor POTSLineFaults”onpage 34
“ProvisionEthernetInterfaceatOLT”onpage 34
Turn-Up
Initialturnupofthe SBUONTinvolvesapplyingpowerandobservingLEDsforstatusinfor
mation.TocompletetheturnupoftheSBUONT,completethefollowingsteps:
1. PlugthegreenUPSconnectorintothemaleconnectoroftheUPS.
2. ChecktoensuretheAC,output,andbatteryLEDsaregre
enandfunctioning.TheUPSis
nowreadyfornormaloperation.
3.
ViewtheLEDsontheSBUONTastheycyclethroughstartupdiagnostics.Aproperly
installedSBUONTcyclesthroughasequenceofoperationsduringstartupandpower
upphases.Table 9onpage 33showsthenormalLEDstatusoncethestartu
pandpow
er
upsequencesarecomplete(approximately30seconds).
InadditiontothefrontpanelLEDs,theSBUONThasLEDsthatareintegraltothe
EthernetRJ45jacks.

Table of Contents

Related product manuals