Total Access 372 Small Business Unit ONT Installation and Maintenance Guide
32 61287722G1-5B
Commissioning and Testing
Thissectionprovidesdetailedinformationonthefollowing :
• “Turn‐Up”
•Dependingonthelocalserviceprov ider’srequirementsthetechnicianmayberequiredto
performadditionaltestsbeyondtheSBUONTontheCustomerProvidedEquipment
(CPE)wiringand/orequipment.Ifthisisthecase,apowermetermaybeusedtotestthe
upstreamanddow
n
streamsignaltypesforvoice,data,andvideo
• “SecuretheUnit”onpage 33
• “Testfor POTSLineFaults”onpage 34
• “ProvisionEthernetInterfaceatOLT”onpage 34
Turn-Up
Initialturn‐upofthe SBUONTinvolvesapplyingpowerandobservingLEDsforstatusinfor‐
mation.Tocompletetheturn‐upoftheSBUONT,completethefollowingsteps:
1. PlugthegreenUPSconnectorintothemaleconnectoroftheUPS.
2. ChecktoensuretheAC,output,andbatteryLEDsaregre
enandfunctioning.TheUPSis
nowreadyfornormaloperation.
3.
ViewtheLEDsontheSBUONTastheycyclethroughstart‐updiagnostics.Aproperly
installedSBUONTcyclesthroughasequenceofoperationsduringstartupandpower‐
upphases.Table 9onpage 33showsthenormalLEDstatusoncethestartu
pandpow
er‐
upsequencesarecomplete(approximately30seconds).
InadditiontothefrontpanelLEDs,theSBUONThasLEDsthatareintegraltothe
EthernetRJ‐45jacks.