Operation
18 / 94 DLT-V72 Series Manual V2.00 Advantech-DLoG
3.5. Operating states
Status of LEDs
DLT-V72 status
Supply voltage
Temperature
OFF OFF Initial state, idle time waiting for a new
ignition signal or for the <Power> key after
switch-off; no voltage supply
OFF FLASHING Temperature sensor faulty
FLASHING OFF DLT-V72 is in standby mode (S3)
OFF ON
Computer will only start if the temperature in
the device is in the range between -30 and
+59 °C again.
ON OFF Computer start-up/normal operational
state/shutdown delay time
ON ON Screen defroster active
ON FLASHING Ambient temperature lies outside of the
permitted range, i.e. < -30 or > +50 °C