Technical data
60 / 94 DLT-V72 Series Manual V2.00 Advantech-DLoG
11.2. Environmental conditions
11.2.1. DLT-V72 without integrated UPS
Operating temperature -30 to +50 °C
Specification according to EN 60068-2-1/2
Storage temperature -30 to +65 °C
Specification according to EN 60068-2-1/2
Relative humidity 10% to 90% at 40 °C relative humidity
Noncondensing
Specification according to EN 60068-2-3
Mechanical vibration
and shock resistance
Class 5M3 according to EN 60721-3-5
US Highway Truck according to MIL-STD 810F
IP protection class IP66 for DLT-V7210 and DLT-V7212
IP65 for DLT-V7210K
11.2.2. DLT-V72 with integrated UPS (optional)
The environmental conditions are described in the following chapter:
12.1 Integrated UPS (optional)