AfiMilk MPC Installation Manual 104
Chapter
9
Cleaning& Maintenance
Fault Alerts
Three types of fault alerts may be displayed during or after milking:
o Outputs Alert – This alert indicates an overcurrent at one of the outputs
(meaning a device may be short-circuiting). Apparatus controlled by
AfiMilk MPC and their corresponding fault alerts are listed below.
The fault indication format is
E01
alternating with
Out#
(# = number of output).
If an output alert appears, try pressing one of the keys of the control box. If the problem
persists OR if the alert appears again, the device needs to be replaced or fixed.
Output Message Device Correlated
Out1 Removal Piston Solenoid
Out2 AfiLite Valve Solenoid
Out3 Vacuum Valve Solenoid
Out4 Pulsator Front
Out5 Pulsator Rear
o Communication Fault – This fault alert indicates a momentary failure in
communication. The error display format for this fault is
E 03
.
If a Communication Fault alert appears, try pressing one of the keys of the control box. If
the problem persists, OR if the alert appears again, you must replace the AfiMilk MPC
control box.
o Milk Dump Delay – AfiMilk MPC dumps the portions of milk into the milk
line. The design of AfiMilk MPC body allows fast discharge of the milk
when the valve is opened. Delays in milk discharge may cause
measurement inaccuracies alongside delays in removal. Error messages
E
02
and
E02F
indicates milk discharge delay.