AfiMilk MPC Installation Manual
51
First Time Operation
Chapter
7
Loading Default Parameter Values
Afimilk MPC is supplied with standard parameter values pre-loaded in its operating
system. In some countries, local regional parameter values are used. The standard value
of the parameter
Load
is
0
. If you are using different set of parameters, use your local load
number provided by afimilk.
There are two procedures for loading preset parameters values:
o Full load – This procedure replaces all of the parameters values stored in the
control unit, except stall ID number. Carry out "Full Load" procedure at system
startup OR when replacing a faulty display.
o Partial load– This procedure replaces operational parameters with new values,
preserving existing calibration values as well as stall ID number. Use this procedure
if parameter load at operating parlor is needed.
Parameters Load Procedure
For loading parameters the milk meter need to be in cleaning mode. The status of the
"Cancel ACR "Indicator determines a partial or full load procedure:
o Full load is indicated by an illuminated LED indicator .
o Partial load is indicated by an extinguished indicator .
Select your preferred Load procedure by pressing the "Cancel ACR" key. Then:
1.
Press four times and then press to access the load option
.
2.
Ld00
appears on the display panel. (
00
represents the number of the set of parameter
presently in the meter.)
3.
Type the number of your local load OR use
00
(default load number) to select the desired
set of parameter values
.
4.
Press to Load parameters OR press to abort
.
The regional parameter values have been loaded.