AfiMilk MPC Installation Manual
75
First Time Operation
Chapter
7
Accuracy Adjustment
AfiMilk MPC milk meters are supplied with default
adjustment calibration values. If after initial setup
(see adjustment per air intake explained above)
inaccuracies of milk measurements vs. bulk tank
OR in specific milk meters are found,
G
&
H
parameters values may need further adjustment.
As illustrated in the chart here, initial calibration
is performed by adjusting the value of
G
parameter. If accuracy is not achieved by
correcting the value of
G
, corrections to the value
of
H
is needed.
The following section explains how to calculate
the adjustment value of parameters
G
&
H
per
deviation in measurement.
Air admission
measurements and
adjustment of G value
Accurate?
Milk test measurements
OR comparison to bulk
tank
Correct the value of G -
2.5G units per 1%
inaccuracy
Accurate?
Correct the value of H -
5H units per 1%
inaccuracy
End