First Time Operation
5. Press -
F5
flashes indicating that editing is enabled.
6. Type the desired value.
7. Press to confirm the change OR to cancel the change.
After editing and saving all the parameters requiring change in the group, press to
return to general programming mode. From this mode you may navigate to another
group by entering the group number (1, 2, 3, or 4).
Parameter Groups definitions
The following tables specify parameters in each group and their shortcut access numbers.
Group 1 – Cow parameters
Shortcut
Number
Symbol
Parameter
Range
Units Parameter Type
1 F1 1-50 Sec. X 10
Minimal Milking T for
First Attachment
2 F2 6-50 Seconds
Valve opening interval
to trigger removal
3 F5 0-12 Sec. X 10
Second Attachment
Premilk Time
4 PP List ppm Pulsation Rate
5 Pr List % Pulsation Ratio
6 StP List ppm Stimulation PPM
7 Sd 0-99 Seconds Stimulation Duration
8 Str List %
Stimulation Operation
Ratio
9 AP 0- 10 No. of Pulses
Pulsation ratio of
50:50 for number of
pulses at the
beginning of milking
- St 0-50 Seconds Strip Threshold
- F4 0/1 Enable/Disable