AfiMilk MPC Installation Manual 58
Chapter
7
First Time Operation
Vacuum valve & Milk Sweep
Milk residues left in the milking claw and hose after cluster removal often drip on the floor
and left inside the liners. This may cause cross contamination between a sick cow to the
cow milked after her at the same milking machine. This feature if enabled, allows
sweeping milk residues. Milk sweep opens the vacuum valve for a short time, sucking
atmospheric air through the cluster, now hanged at the stall thus sweeping milk residues
into the milk meter body.
Milk Sweep Parameters
Milk sweep starts 2
seconds after cluster
removal. The time for
valve opening for
atmospheric air is
defined by the
parameter
SL
(in
seconds).
If you wish to cancel the SWEEP function, set SL=0.