EasyManua.ls Logo

AfiMilk MPC 3 - Afimilk MPC Start-Up Sequence

AfiMilk MPC 3
116 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AfiMilk MPC Installation Manual 50
Chapter
7
First Time Operation
Afimilk MPC Start-up Sequence
After power to the Afimilk MPC milk meter is switched on, the following occurs:
1. The milk meter software version is displayed for a few seconds to be replaced by the stall
number set in the display. Stall number appears for several seconds to be replaced by
Cleaning Mode display (When activating an Afimilk MPC for the first time,
Id66
is
displayed as stall number).
2. Afimilk MPC milk meter starts-up in cleaning mode. Cleaning mode is indicated by
illuminated red LED at the cleaning mode key . In this mode, the milk valve opens
and closes regardless of the amount of liquid in the milk meter body.
3. Once in Cleaning mode, temperature reading, such as
24c
(24°C) appears. This is the
wash temperature* detected by the integrated thermistor in the milk meter body.
a.
If the moment of power-up is not during a milking session, or if the meter is not
connected to a computer:
appears for a few seconds to be replaced by the pulsation indicator:
Press to alternate between cleaning and removal mode.
When the red LED is lit and is displayed (with the pulsation indicator
alternating), the milk meter is in cleaning mode.
NOTE
Temperature reading is available for Afimilk MPC incorporating the Pro
body (including thermistor). Afimilk MPC displays installed with AfiLite+
bodies, will NOT display wash temperature!