AfiMilk MPC Installation Manual 56
Chapter
7
First Time Operation
As explained above, cluster removal occurs after a threshold delay time. This time may be
converted to represent removal flow rate. Below is a simple formula to calculate the
required value of
F2
per desired flow rate for removal.
*At the end of milking, about 200grams (0.20 Kg = 0.44lb [6.5 oz.]) of milk is released each time
the milk valve is opened for dumping milk to the milk line.
-
Smooth Removal
Shutting the vacuum off when the pulsation is still active releases the liner vacuum
pressure off the teat. is a short delay time between the vacuum shut-off and cluster
removal (pulsation stops with removal piston retraction) allowing the liner to smoothly
slide off the teat before it is pulled up by the removal piston.
-
Quick Cluster Removal
Quick removal is an option for early removal of the cluster for cows with low yield. This
feature prevents over-milking of cows at the beginning of lactation, when their production
is low.
Quick removal is activated if during the pre-milk time (afimilk delay parameter F1), the
cow gave the entire yield expected from it. In such situations, the cluster removal after
pre-milk time will be at a faster flow rate (removal process is initiated at half of the regular
removal delay [F2]).
The quick removal option is activated via a user-configured parameter F4 that may be set
to either enabled or disabled. In addition, AfiFarm allows the user to assign a code to
enable quick removal for specific cows (example: all cows within 10 days from calving).
value of
=
60 seconds
Flow Rate for Removal
(kg/min)
X 0.20 kilograms (0.44Lb) *
value of
=
60 seconds
0.8
X
0.20 kilo
grams (0.44Lb) per minute
If 0.8Kg/min (
1.76Lb/min
) is the desired flow rate for removal
value of
=15