System Management
7750 SR OS Basic System Configuration Guide Page 273
Filters
In a TOD suite, filters that have entries with time-ranges may not be selected. Similarly, filter
entries with a time-range may not be created while a TOD suite refers to that filter. QoS policies
and filters referred to by a TOD suite must have scope “template” (default).
The following syntax is used to configure TOD-suite egress parameters.
CLI Syntax: config
cron
tod-suite tod-suite-name create
egress
filter ip ip-filter-id [time-range time-range-name]
[priority priority]
filter ipv6 ipv6-filter-id[time-range
time-range-name] [priority priority]
filter mac mac-filter-id[time-range time-range-
name] [priority priority]
qos policy-id [time-range time-range-name] [priori-
ty priority]
scheduler-policy scheduler-policy-name [time-range
time-range-name]
Example
: config>cron>tod-suite$ egress filter ip 100
config>cron>tod-suite$
The following command shows an egress IP filter association with filter ID 100.
sim1>config>filter# ip-filter 100 create
A:sim1>config>filter>ip-filter$ entry 10 create
A:sim1>config>filter>ip-filter>entry$
A:sim1>config>cron>tod-suite# egress filter ip 100
A:sim1>config>cron>tod-suite# info detail
----------------------------------------------
no description
egress
filter ip 100
exit
----------------------------------------------
A:sim1>config>cron>tod-suite#
Example:config>cron>tod-suite$ egress qos 101
config>cron>tod-suite$