Common Configuration Tasks
Page 278 7750 SR OS Basic System Configuration Guide
Configuring Manual Synchronization
Note that automatic synchronization can be configured in the config>system> synchronization
context.
CLI Syntax: admin
redundancy
synchronize {boot-env|config}
Example
: admin>redundancy# synchronize config
The following shows the output which displays during a manual synchronization:
A:ALA-12>admin# synchronize config
Syncing configuration......
Syncing configuration.....Completed.
A:ALA-12#
Forcing a Switchover
The force-switchover now command forces an immediate switchover to the standby CPM card.
CLI Syntax: admin>redundancy
force-switchover [now]
Example
: admin>redundancy# force-switchover now
A:ALA-12# admin redundancy force-switchover now
A:ALA-12#
Resetting...
?
If the active and standby are not synchronized for some reason, users can manually synchronize
the standby CPM by rebooting the standby by issuing the admin reboot standby
command on
the active or the standby CPM.