Boot Option Files
7750 SR OS Basic System Configuration Guide Page 197
Show Commands
bof
Syntax bof [cflash-id | booted]
Context show
Description This command displays the Boot Option File (BOF) executed on last system boot or on the specified
device.
If no device is specified, the BOF used in the last system boot displays. If the BOF has been modified
since the system boot, a message displays.
Parameters cflash-id. The cflash directory name. The slot name is not case-sensitive. Use upper or lowercase “A”
or “B” for the slot name.
Values cf1:, cf1-A:, cf1-B:, cf2:, cf2-A:, cf2-B:, cf3:, cf3-A:, cf3-B:
booted — Displays the boot option file used to boot the system.
Output Show BOF Fields — The following table describes BOF output fields.
Table 25: Show BOF Output Fields
Label Description
primary-image
The primary location of the directory that contains the runtime images
of both CPM and IOM.
primary-config
The primary location of the file that contains the configuration.
primary-dns
The primary DNS server for resolution of host names to IP addresses.
secondary-image
The secondary location of the directory that contains the runtime
images of both CPM and IOM.
secondary-config
The secondary location of the file that contains the configuration.
secondary-dns
The secondary DNS server for resolution of host names to IP
addresses.
tertiary-image
The tertiary location of the directory that contains the runtime images
of both CPM and IOM.
tertiary-config
The tertiary location of the file that contains the configuration.
address
The IP address and mask associated with the CPM Ethernet port or the
secondary CPM port.
tertiary-dns
The tertiary DNS server for resolution of host names to IP addresses.