Date and Time Commands
Page 350 7750 SR OS Basic System Configuration Guide
server-address
Syntax server-address ip-address [version version-number] [normal | preferred]
[interval seconds]
no server-address
Context config>system>time>sntp
Description This command creates an SNTP server for unicast client mode.
Parameters ip-address — Specifies the IP address of the SNTP server.
version version-numberSpecifies the SNTP version supported by this server.
Values 1 — 3
Default 3
normal | preferred — Specifies the preference value for this SNTP server. When more than one
time-server is configured, one server can have preference over others. The value for that server
should be set to preferred. Only one server in the table can be a preferred server.
Default normal
interval secondsSpecifies the frequency at which this server is queried.
Values 64 — 1024
Default 64