System Management
7750 SR OS Basic System Configuration Guide Page 371
System Synchronization Configuration Commands
sync-if-timing
Syntax sync-if-timing
Context config>system
Description This command creates or edits the context to create or modify timing reference parameters.
This command is not enabled in the 7750 SR-1.
Default not enabled (The ref-order must be specified in order for this command to be enabled.)
abort
Syntax abort
Context config>system>sync-if-timing
This command is required to discard changes that have been made to the synchronous interface
timing configuration during a session.
Default No default
begin
Syntax begin
Context config>system>sync-if-timing
Description This command is required in order to enter the mode to create or edit the system synchronous
interface timing configuration.
Default No default
bits
Syntax bits
Context config>system>sync-if-timing
Description This command enables the context to configure parameters for the Building Integrated Timing Supply
(BITS).
Default disabled