7–3Set Up or Simulate Rotary Cam Limit Switches
Publication
65566.5.1 - October 1996
This
RCLS:
Your
1
ON OFF:
Typical
ON OFF:
Turns OFF
at a position:
Turns ON
at a position:
ACAM
Remains ON for the entire stroke except of an Off span during upstroke (Figure 7.2)
290
o
250
o
1
Important: To determine exact settings, refer to recommendations provided by the press manufacturer.
Set the ACAM-off span to the number of degrees (0
0
-
90
0
) according to
the speed of the press (0-200 strokes per minute) from Figure 7.2. ACAM
contacts should remain open for at least two program scans.
Figure 7.2
AntiRepeat
Contacts: Upstroke ONspan vs. Press Speed
200
180
160
30
60
90
0
0
0
OFF Span of Antirepeat Contacts During Up Stroke
140
120
100
80
60
40
20
0
Press
Speed
(SPM)
Important: When using RCLSs, you must also use the hardware
motion detector for the subject chassis (A or B or both). Do NOT
delete the motion detector switch (I/O module group 2, Figure 3.4
or 3.16) and do NOT write ladder logic for motion detection with
a resolver input (Figure 4.10).
Important: To set up your real or simulated ACAM, BCAM, and
TCAM on/off positions according to Figure 7.1 and Table 7.B, go
to the next page.