Troubleshooting with Fault Codes, Operator Prompts, and Snapshot Status BitsC–6
Publication
65566.5.1 - October 1996
B168/ How to Correct the FaultEffect of FaultCause of FaultSuggested Message
138* Aux Valve 1
Failed to Turn ON
Valve failed to energize
when output was turned ON.
Press will not cycle. Check valve and valve wiring.
139* Aux Valve 1
Failed to Turn OFF
Valve failed to deenergize
when output was turned OFF.
C/B power is removed. Check valve and valve wiring.
140* Aux Valve 2
Failed to Turn ON
Valve failed to energize
when output was turned ON.
Press will not cycle. Check valve and valve wiring.
141* Aux Valve 2
Failed to Turn OFF
Valve failed to deenergize
when output was turned OFF.
C/B power is removed. Check valve and valve wiring.
142* Aux Valve Stem 1
Failed to Turn ON
Valve failed to energize
when output was turned ON.
Press will not cycle. Check valve and valve wiring.
143* Aux Valve Stem 1
Failed to Turn OFF
Valve failed to deenergize
when output was turned OFF.
C/B power is removed. Check valve and valve wiring.
144* Aux Valve Stem 2
Failed to Turn ON
Valve failed to energize
when output was turned ON.
Press will not cycle. Check valve and valve wiring.
145* Aux Valve Stem 2
Failed to Turn OFF
Valve failed to deenergize
when output was turned OFF.
C/B power is removed. Check valve and valve wiring.
146* Clutch Valve 1
Failed to Turn ON
Valve failed to energize
when output was turned ON.
Press will not cycle. Check valve and valve wiring.
147* Clutch Valve 1
Failed to Turn OFF
Valve failed to deenergize
when output was turned OFF.
C/B power is removed. Check valve and valve wiring.
148* Clutch Valve 2
Failed to Turn ON
Valve failed to energize
when output was turned ON.
Press will not cycle. Check valve and valve wiring.
149* Clutch Valve 2
Failed to Turn OFF
Valve failed to deenergize
when output was turned OFF.
C/B power is removed. Check valve and valve wiring.
150* Clutch Valve Stem 1
Failed to Turn ON
Valve failed to energize
when output was turned ON.
Press will not cycle. Check valve and valve wiring.
151* Clutch Valve Stem 1
Failed to Turn OFF
Valve failed to deenergize
when output was turned OFF.
C/B power is removed. Check valve and valve wiring.
152* Clutch Valve Stem 2
Failed to Turn OFF
Valve failed to deenergize
when output was turned ON.
Press will not cycle. Check valve and valve wiring.
153* Clutch Valve Stem 2
Failed to Turn OFF
Valve failed to deenergize
when output was turned OFF.
C/B power is removed. Check valve and valve wiring.
154* Clutch Valve Fault Any of 134153 detected. C/B power is removed. Check valve and valve wiring.
155159 Spare
* To clear this latched fault bit, you must enable the fault reset bit or turn the modeselect switch to OFF.
Whenever a PLC-5/x6 processor detects conditions worthy of a
prompt, it sets corresponding bits in Bit File 169 in the data table.
We list conditions for which the software is designed to detect and
signal a prompt.
We recommend that you program a method to display bit numbers of
detected prompt conditions. Then, you can respond quickly by
looking them up in the following table.
Prompts for
Operating the Press