2–7Define Your Control System Characteristics
Publication
65566.5.1 - October 1996
Configuration Worksheet
1.
V
erify Your Factoryconfigured Options
Do this by inspecting the label on the software diskette in your
Application Package and matching it to your order number,
such as cat. no. 6556-PA
1
H
2
P
3
K
4
:
Factoryconfigured Options (by Cat. No.) Code Ordered Received
1
Method to Start
Arm continuous PB, or A
Continuous Mode Strokeandahalf S
2
Onthehop
With this feature H
Omit this feature 0
3
Active Pin
With active pin, or P
in Run Stations Omit active pin 0
4
Hardware Kit
Full kit K
Minimum bundle
1
M, M1M5
1
For hardware lists of various kits, see the C/B Packing Data, publication 65565.1.
2. Assign Outputs
Match 1771-OD16 outputs to your clutch/brake valves.
For output wiring, refer to wiring drawing sheet 9.
Output 1771OD16 Address Your Designation
Clutch 1 AO:005/02 and BO:005/02
Clutch 2 (Brake) AO:005/03 and BO:005/03
Auxiliary 1 AO:005/06 and BO:005/06
Auxiliary 2 AO:005/07 and BO:005/07
Microinch 1 AO:005/12 and BO:005/12
Microinch 2 AO:005/13 and BO:005/13
Auxiliary valves in unison with_ or in opposition to ___clutch valves.
If not used, set corresponding command bit