Chapter 3
Publication
65566.5.1 - October 1996
Customize the Wiring
to Suit Your Application
In this chapter, we present default configurations of the control
system, and show you how to modify them to meet your application
requirements. We:
list default wiring configurations and modifications you can make
explain how to install wiring drawing diskettes on your hard drive
explain how to perform the wiring modifications
give example figures showing completed modifications
Here are the modifications that you can make to customize the
wiring of the control system to suite your application.
For This Category Use This Default Configuration Or, Modify Your Wiring Drawings to:
rotary cam limit switches hardwired switches replace RCLSs with resolvers
crowbar hardwired relays (you must set B151/15) delete the crowbar relay circuit
air pressure hardwired switch replace with an analog pressure sensor
main motor forward hardwired switch replace with a drive feedback
motion detector hardwired switch replace with resolver input
run stations use all four delete up to three
active pin active pin is wired delete active pin wiring
arm continuous hardwired switch replace arm continuous with strokeandahalf
valve stem feedback valves with external fault detection use valves with internal fault detection
press mode selector 7position switch delete unused selector positions
auxiliary valves use auxiliary valves for soft " C/B or dump delete them
microinch valves use microinch buttons and valves delete them
We organized the modifications by I/O module group number
according to the wiring drawing on which the configuration is
presented. Modifications are also grouped according to:
ungrounded ac system power
grounded ac system power
Chapter Objectives
How to Customize the
Default Wiring

Table of Contents

Related product manuals