5–3Assigning Passwords to Your Program and Data Files
Publication
65566.5.1 - October 1996
Data Table Privileges
We assigned R (read only) or RW (read/write) privileges to classes 1-4
for controlling access to data files. To view the Data Table Privileges
screen that allocates these privileges, follow this procedure for 6200
series software (the procedure for AI5 software would be similar):
1. Start at the Main Menu.
2. Press [F7] - General Utility.
The system displays the General Utility screen.
3. Press [F1] - Memory Map.
The system displays the Memory Map screen.
4. Press [F2] - Modify Privileges.
You get the Data Table Privileges screen.
We assigned the following privileges for classes 1-4 at the factory.
File Type Class 1 Class 2 Class 3 Class 4
0
O output RW RW RW RW
1 I input RW RW RW RW
2 S status RW RW RW RW
3 B binary or bit RW RW RW RW
4 T timer RW RW RW RW
5 C counter RW RW RW RW
6 R control RW RW RW RW
7 N integer RW RW RW RW
8 F floating point RW RW RW RW
919 reserved for customer RW RW RW RW
20 B binary or bit RW R R R
21 T timer RW R R R
2228 reserved for customer RW RW RW RW
29 N integer RW R R R
30149 reserved for customer RW RW RW RW
150 B binary or bit RW RW RW RW
151 B binary or bit RW RW RW RW
152 B binary or bit RW RW RW RW
153159 reserved for customer RW RW RW RW
160 B binary or bit RW R R R
161 N (only in processor B) RW R R R
162 T timer RW R R R
163 BT block transfer RW R R R
164 N integer RW R R R
165 R control RW R R R
166 N integer RW R R R
167 N integer RW R R R
168 B binary or bit RW R R R
169 B binary or bit RW R R R