2–10 Define Your Control System Characteristics
Publication
65566.5.1 - October 1996
7. Select Optional Command Bits for C/B Interface Logic
Select command bits for your clutch/brake interface (PF15).
We grouped bits by similar kind. For logic examples, see chapter 4.
Important: Some bits are listed more than once, based on usage.
To: Use this Control Bit: At Addr.
n
Simulate the brakemonitor (BCAM) with a resolver
Brake Monitor
1
B151/00
Simulate the takeover (TCAM)
Takeover
1
B151/01
Simulate the antirepeat (ACAM)
Antirepeat
1
B151/02
Enable run buttons
Permit Cycle Start B151/03
Monitor safety interlocks
Permit Run
B151/04
Enable press motion in downstroke, after pressing buttons
Permit Downstroke (Delayed Start)
B151/05
Stop press operation in upstroke
Permit Upstroke
B151/06
Turn OFF clutch output at next top zone
Top Stop
B151/07
Start the press automatically in remote automatic modes
Simulate Run Buttons
B151/25
Start the arming timer for continuous on demand
Arm for Continuous on Demand
B151/27
Start inch with inch buttons and this bit set remotely
Inch Output Enabled
B151/28
Lets you start auto single stroke without cycling the press
Initiate Automatic Single Stroke
B151/29
Allow inching
Permit Inch B151/08
Simulate hardwired inch buttons during setup
Simulate Inch Buttons
B151/09
Allow simulated inch buttons during setup
Remote Inch Mode
B151/10
Allow simulated microinch buttons during setup
Remote Microinch Mode
B151/24
Simulate a pressure switch with an analog input
Clutch Pressure On B151/11
Simulate a motion switch with a resolver input
Press in Motion
1
B151/12
Simulate a motion switch with a drive input
Main Motor Forward
B151/18
Select the operating mode remotely with your ladder logic.
Remote Inch Mode B151/10
Main selector switch must be switched to remote mode.
Remote Singlestroke Mode B151/13
.
Remote Continuous Mode B151/14
Remote Microinch Mode B151/24
Remote Automatic Singlestroke Mode B151/26
Use a pushbutton to reset the processor after a C/B fault Fault Reset B151/23
Enable the crowbar relay circuit to deadshort the ac line Enable Crowbar Relay B151/15
Determine the sequencing of auxiliary valve operation Aux Valve 1 Cycles with Clutch Outputs B151/16
(Also used with bits 19 and 22 for soft " C/B valves.) Aux Valve 2 Cycles with Clutch Outputs B151/17
Program soft" clutch and and brake valve operation
Aux Valve 1 Enabled B151/19
(Also used to delete the use of auxiliary valves 1 and 2.)
Aux Valve 2 Enabled B151/22
Delete valvestem feedback when using valves with
Aux Valve Stems Enabled B151/20
internal fault detection
C/B Valve Stems Enabled
B151/21
1
for resolver inputs, only