Description of Operating ModesA–4
Publication
65566.5.1 - October 1996
Figure A.2
Typical
Operational Sequence for Downstroke in Single Mode
Select single mode.
Have you released all Run buttons
since the previous stroke?
Have you pressed all Run buttons
concurrently? (see table below)
Both processors energize their
outputs to actuate the clutch for
downstroke.
Have you released
a Run button?
No
Yes
No
Is the press into the
upstroke zone?
Go to R2.
(Figure A.3)
Both processors deenergize their
outputs to stop the press.
Have you released, then pressed
all Run buttons concurrently?
Yes
Yes
No
Yes
Is the motor running forward?
Yes
No
No
Yes
R1
No
For This Mode: Replace Run Buttons With: Bit Number:
Remote Inch
Simulate Inch Buttons
Remote Micro-inch
Command Bit
B151/09
Remote Automatic Single
Simulate Run Buttons
Continuous on Demand
Command Bit
B151/25