4–21Write Ladder Logic
Publication
65566.5.1 - October 1996
This is the list of internal timers.
The time base is 0.01 second for all timers
.
Timer
Preset Your Preset Address Bit
Crowbar Relay Weld 100 T162:2 B152/2
Crowbar Relay Failed to Turn On 100 T162:3 B152/3
Seal relay Failed to Turn On 100 T162:5 B152/5
Seal Relay Weld 100 T162:6 B152/6
EStop Relay Failed to Turn On 100 T162:7 B152/7
EStop Weld 100 T162:8 B152/8
No Valid Mode Selected 300 T162:10 B152/10
Clutch/Brake Mode Mismatch 200 T162:11 B152/11
Station # 1 Antitiedown 300 T162:12 B152/12
Station # 2 Antitiedown 300 T162:13 B152/13
Station # 3 Antitiedown 300 T162:14 B152/14
Station # 4 Antitiedown 300 T162:15 B152/15
Multiple Active Station Antitiedown 300 T162:16 B152/16
Inch Button Antitiedown 300 T162:17 B152/17
Clutch/Brake Air Pressure 300 T162:19 B152/19
Clutch/Brake Air Pressure Exhausted 300 T162:20 B152/20
BCAM Soft Cam Compare 100 T162:21 B152/21
TCAM Soft Cam Compare 100 T162:22 B152/22
ACAM Soft Cam Compare 100 T162:23 B152/23
Motion Detector Watchdog 300 T162:28 B152/28
Uncommanded Motion Detected 300 T162:29 B152/29
Microinch Feedback Valve A Off 100 T162:30 B152/30
Microinch Feedback Valve B Off 100 T162:31 B152/31
Microinch Feedback Valve A On 100 T162:32 B152/32
Microinch Feedback Valve B On 100 T162:33 B152/33
Arm Continuous Button 500 T162:35 B152/35
Arm for Continuous on Demand 30,000 T162:36 B152/36
Clutch 1 Failed to Turn On 100 T162:42 B152/42
Clutch 1 Failed to Turn Off 100 T162:43 B152/43
Clutch 2 Failed to Turn On 100 T162:44 B152/44
Clutch 2 Failed to Turn Off 100 T162:45 B152/45
Clutch Valvestem 1 Failed to Turn On 100 T162:46 B152/46
Clutch Valvestem 1 Failed to Turn Off 100 T162:47 B152/47
Clutch Valvestem 2 Failed to Turn On 100 T162:48 B152/48
Clutch Valvestem 2 Failed to Turn Off 100 T162:49 B152/49
Auxiliary Valve 1 Failed to Turn On 100 T162:50 B152/50
Auxiliary Valve 1 Failed to Turn Off 100 T162:51 B152/51
Auxiliary Valve 2 Failed to Turn On 100 T162:52 B152/52
Auxiliary Valve 2 Failed to Turn Off 100 T162:53 B152/53
Auxiliary 1 Valvestem Failed to Turn On 100 T162:54 B152/54
Auxiliary 1 Valvestem Failed to Turn Off 100 T162:55 B152/55
Auxiliary 2 Valvestem Failed to Turn On 100 T162:56 B152/56
Auxiliary 2 Valvestem Failed to Turn Off 100 T162:57 B152/57
Automatic Singlestroke Timeout 300 T162:58 B152/58