158 Rockwell Automation Publication 1756-UM022D-EN-P - May 2017
Appendix A Status Indicators
#0108 Invalid Connection Type #0801 Incompatible Multicast RPI
#0109 Invalid Connection Size #0802 Invld Safety Conn Size
#0110 Module Not Configured #0803 Invld Safety Conn Format
#0111 RPI Out of Range #0804 Invld Time Correct Conn Format
#0113 Out of Connections #0805 Invld Ping Intrvl EPI Multiplier
#0114 Wrong Module #0806 Time Coord Msg Min Multiplier
Code Message Code Message
I/O Fault Messages (continued)
Code Message Code Message
#0807 Time Expectation Multiplier #FE08 Invalid Output Data Pointer
#0808 Timeout Multiplier #FE09 Invalid Output Data Size
#0809 Invld Max Consumer Number #FE0A Invalid Output Force Pointer
#080A Invld CPCRC #FE0B Invalid Symbol String
#080B Time Correction Conn ID Invld #FE0C Invalid Scheduled P/C Instance
#080C Safety Cfg Signature Mismatch #FE0D Invalid Symbol Instance
#080D Safety Netwk Num Not Set OutOfBx #FE0E Module Firmware Updating
#080E Safety Netwk Number Mismatch #FE0F Invalid Firmware File Revision
#080F Cfg Operation Not Allowed #FE10 Firmware File Not Found
#0814 Data Type Mismatch #FE11 Firmware File Invalid
#FD01 Bad Backplane EEPROM #FE12 Automatic Firmware Update Failed
#FD02 No Error Code #FE13 Update Failed - Active Connection
#FD03 Missing Required Connection #FE14 Searching Firmware File
#FD04 No CST Master #FE22 Invalid Connection Type
#FD05 Axis or GRP Not Assigned #FE23 Invalid Unicast Allowed
#FD06 SERCOS Transition Fault #FF00 No Connection Instance
#FD07 SERCOS Init Ring Fault #FF01 Path Too Long
#FD08 SERCOS Comm Fault #FF04 Invalid State
#FD09 SERCOS Init Node Fault #FF08 Invalid Path
#FD0A Axis Attribute Reject #FF0B Invalid Config
#FD1F Safety Data Fault #FF0E No Connection Allowed
#FD20 No Safety Task Running #FE22 Invalid Connection Type
#FD21 Invld Safety Conn Parameter #FE23 Invalid Unicast Allowed
#FE01 Invalid Connection Type #FF00 No Connection Instance
#FE02 Invalid Update Rate #FF01 Path Too Long
#FE03 Invalid Input Connection #FF04 Invalid State
#FE04 Invalid Input Data Pointer #FF08 Invalid Path
#FE05 Invalid Input Data Size #FF0B Invalid Config
#FE06 Invalid Input Force Pointer #FF0E No Connection Allowed