BIBI 850-BL Use and maintenance manual Rev.00
67
4.2.4 Timer
The ground control console has the timer in the central position. This instrument begins to count
the moment in which the platform's combustion engine is started, while counting ends when the
engine is switched off.
Platform descent, which can also be performed with the engine OFF, is not included in the hour
count.
The purpose of the instrument is to warn the user when the platform has reached the number of
work hours after which MAINTENANCE is required.
4.2.5 Easy-Drive System (ED-S)
Moving the switch on the pushbutton panel to the "ED-S" position activates a special function
that allows you to control the rotation on the platform, especially when operating on cultivated
or grassy terrain, so that the tracks do not rip the cultivation during right or left rotation.
When activated, the function controls not only the track involved in the rotation but also the
rotation of the other track in a controlled manner.