BIBI 850-BL Use and maintenance manual Rev.00
74
Ch
apter 5
Emergency procedures
5.1 Emergency manual descent
Following a failure in the electrical system or hydraulic circuit, the platform DESCENT manoeuvre
can be performed from any height by means of the emergency control at ground level.
In this case, the operator on the ground uses the hydraulic valve control located in the rear of the
platform near the access ladder (remember that safe use of the platform requires at least one
operator on the ground).
AT
TENTION: THIS MECHANISM MUST ONLY BE USED IN AN EMERGENCY, i.e. ELECTRICAL OR
HY
DRAULIC FAILURE.
5.2 Transport of the machine in an emergency
If the combustion engine and, thus, the hydraulic circuit cannot be started, emergency transport of
platform BIBI-850-BL is performed in the same way as manual transport.
Use a CE certified beam (not included) that should have a vertical distance of 350 mm between the
hook and chain and, using hooks and steel ropes hooked to the holes marked with signs (see photo
below). The ropes must possess safety factor 5.
PULL THE LEVER TO RELEASE THE
DESCENT VALVE