BIBI 850-BL Use and maintenance manual Rev.00
77
Operation
Type
Frequency
Scr
ews-nuts-bolts-plug ring nuts
Check and tighte
n
Be
fore each use
Structure Vi
sual check Before each use
Dam
age to tubes and cables
Vi
sual check
Monthl
y
Arti
culations Greasing Monthly
Runners Greasing Monthly
H
ydraulic oil reservoir level Check Before each use
H
ydraulic oil reservoir level
Replac
ement
Ever
y 2 years.
Pressure relief valve of lift circuit Operational check Yearly
Ba
ttery status
Operati
onal check
Be
fore each use
H
ydraulic filters Replacement Every 2 years.
Inclinom
eter
Check operation Ye
arly
Overlo
ad monitoring device Check operation Yearly
Decals and data plates Check Yearly
Mi
croswitches Operational check Yearly
El
ectric insulation monitoring device
Check operation Ye
arly
Manual emergency devices Check operation Yearly
H
ydraulic lift circuit
Vi
sual check
Ye
arly
Moto
r oil Level check Before each use
Moto
r oil
Replac
ement
Ever
y 100 hours *
Ai
r filter Cleanliness Every 50 hours
Ai
r filter
Replac
ement
Ever
y 300 hours
Sp
ark plug Check Every 100 hours
Sp
ark plug
Replac
ement
Ever
y 300 hours
Track tension Check Before each use
T
rack tread
Check Be
fore each use
T
racks Replacement
<10 mm tread or if cuts are
noted
T
rack reduction gear oil level
Check Monthl
y
T
op track roller and frame Check Every 6 months
Parking brake Check operation Every 6 months
* the engine o
il must be changed for the first time after the platform has been used for 20 hours.