± 0.1% of full scale, 16 Hz - 500 Hz
Will compensate for up to 7% of voltage drop up to 2
kHz
From start of voltage change from 5.0 V
RMS
or
higher voltage to within 2% of final value:
No load: 16 ms
Full load: 300 ms
(16 ms to within 15% of final value)
Distortion (THD
into linear load):
0.5% typical, 1.0% maximum below 100 Hz
1.0% typical, 2.0% maximum 100 Hz - 2000 Hz
AC coupled transformer output
< 0.1 V
RMS
typical
( 20 kHz to 1 MHz at full load )
± 0.02% of full scale per degree C
± 0.015% of full scale under constant load, line and
temperature
2000 VA maximum at full scale voltage, either range
2003RP:
2003RP-AV:
2003RP-HV
Volt Range
135
270
115
230
156
312
A
RMS
5.0
2.5
5.9
2.9
4.3
2.1
A
PEAK
15.0
7.5
17.6
8.8
12.9
6.3
0.0 to Maximum available RMS current for selected
voltage range. Maximum current is available for
output voltage from 50% to 100% of range. Current
derates below 50% of range setting. See derating