1-26
S-4000
Revised 01/2005
e-mail: service@amfreece.cz; parts@amfreece.cz; website: www.amfreece.com
Phones: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
LCD DISPLAY PROGRAMMING
Explanation of Parameters
Parameters with direct access:
SPEEDS (spm, Stitches Per Minute)
SOFT STRT (Soft Start) - Check, if in menu “toggle switches” is “soft strt” set “ON” and in parameter
“soft start” in menu Counters is set needed number of stitches. “SOFT STRT”- soft start settings, which
determines the sewing speed in stitches per minute and the number of stitches to be sewn at the reduced
starting speed.
Ranges: 200 to 1,000 spm
Step increments: 10 spm
Default Setting: 800 spm
ENDspeed - After the home sensor is activated, the last stitches are sewn at a reduced speed during
the buttonhole cutting, thread trimming, and all end of sewing cycle operations.
Ranges: 400 to 1,000 spm
Step increments: 10 spm
Default Setting: 800 spm
TIMERS (ms, Milliseconds)
STRT. DEL (Start Delay) - Delays the start after toeing the Start treadle fully down with the clamps in the
Up position, allows the clamps time to lower and hold the material before the machine starts sewing.
Range: 20 to 200 ms
Step increments: 10 ms
Default Setting: 50 ms
WAIT TM. (Wait Time) - Wait time between sewing cycles, during continuous sewing, which allows the
correct positioning of the fabric for the next buttonhole.
Range: 100 to 2500 ms
Step increments: 10 ms
Default Setting: 350 ms
TRIM TME (Trim Time) - The amount of time the trim knife stays extended before retracting to the home
position.
Range: 30 to 150 ms
Step increments: 10 ms
Default Setting: 50 ms