1-34
S-4000
Revised 01/2005
e-mail: service@amfreece.cz; parts@amfreece.cz; website: www.amfreece.com
Phones: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
LCD DISPLAY PROGRAMMING
Renewal of the set parameters in program “MASTER RESET”
In case that some parameters have accidental value, it is necessary to use function MASTER RESET. This
function rewrite set values by the values set from producer, that are saved in program.
Note: Before you switch the machine on after MASTER RESET, it is necessary to set the values according
to the enclosed example from producer.
Push , and together.
When all three buttons are pushed, switch the machine on by black switch on the switch box.
PUSH “SET” and TO RESET start alternately flash on the display. If you want to do MASTER RESET,
push the SET button during the flashing.
OPERATING MODE appears on the display. You can enter to hidden parameters after MASTER
RESET.
Note: If you do not catch push the SET button during flasing, OPERATING MODE appears on the
display, but function MASTER RESET is not functional.