EasyManua.ls Logo

Ammann ASC 110 - After 250 Hours of Operation (3 Months); Checking the Engine Inlet Piping

Ammann ASC 110
194 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
120 ASC 110
1
3
2
3.6. Individual Operations of Maintenance
After 250 hours of operation (3 months)
3.6.9. Checking the engine inlet piping
Check the tightness of engine inlet piping.•
Check for any damage of the rubber hose of the inlet piping •
leading from the lter, and for missing clamping clips.
Check again tightness between the bonnet 2 and the air •
cleaner 3.
Replace damaged sealing 1 with a new one.•
Do not operate the machine if the sealing
between the bonnet and the air cleaner
is damaged or not tight.

Table of Contents