160 ASC 110
396034
1 of 1
HIDE
396286
WARNING
WATER IN FUEL DETECTED
FMI 0SPN 97
282043
1
2
3.6. Individual Operations of Maintenance
3.6.33. Cleaning of the water separator on the
fuel lter
Yellow indicator lamp signal.•
The message. SPN 97 is displayed.•
Twist the separator valve , drain the water from lter.•
Shut o the engine during separator
draining!
Drain water/fuel into a container and
dispose of in accordance with local envi-
ronmental regulations.
If you drained over 60 cm•
3
[0.63 quarts] of fuel rell the fuel
into fuel lter. Open the bleed screw 1. Unscrew a transfer
pump and operate until the fuel owing is free of air.
Do not bleed the fuel with the hot en-
gine owing out fuel may couse a re!
No smoking et Work on fuel system!
Drain fuel into a container and dispose
of in accordance with local environmen-
tal regulations.