3.6.38. Vibrator cooling mixture
The drum water lling is a lling for the whole service life •
and it is not necessary to exchange it. The lower plug is used
for draining the water, the upper plug is for lling up and
checking the water level. When draining the water, make
sure that the drum is in an inclined position for draining the
liquid. After the drum has been lled up, drive the machine
so that the plugs are at an opposite position (upward). Fill
the liquid up to the level according to chapter 3.2.8.
Do not operate the machine without the
drum being lled with water!
ACE drum