EasyManua.ls Logo

Ammann ASC 110 - Page 143

Ammann ASC 110
194 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
137ASC 110
2
1
MAINTENANCE MANUAL
Rell oil to the upper oil level mark 2. Oil charge is 11 l (12 qt) •
inclusive of ll oil lter.
NOTE
After relling, start the engine for 2 - 3 min. Check tightness •
of drain plug and lter.
Stop the engine, wait for approx. 5 min. until oil runs down •
to the engine sump. Then check the level with oil dipstick.
Beware of scalding when draining hot
oil. Let oil cool down to less than 50 °C
(122 °F).
Follow the re safety measures!
Exchange oil after 6 months at the latest,
if 500 hours of operation have not been
reached by that time. Exchange oil in the
interval that comes rst.
Use recommended lters - see Spare
parts catalogue. Use recommended oil -
see chapter 3.2.1.
Collect drained oil; do not let it soak into
the ground.
Used oil and lters are environmen-
tally dangerous waste - have them
liquidated.
Fill the engine through the ller 1.•

Table of Contents